Fire and Safety

Emergency lighting is integral part of your buildings safety system, which enables people to evacuate the building quickly and safely in an event of a fire or a power cut. It is essential that an Emergency lighting system is designed installed and maintained correctly to ensure the system operates when required in an emergency situation.

Design We offer a complete design service to ensure that the system complies to the requirements of BS 5266-1:2011 Emergency lighting – Part 1: Code of practice for the emergency escape lighting of premises. With a combination of maintained, non maintained and exit lighting we can design a system that fits your building.

Installation

Kingston Fire and Electrical have the ability to deliver high standard of installation in to your premises with a minimum of disruption to the building. We have the experiment to deliver quality installation from a surface installation to a fully finished flush installation.

Testing

Testing requirement of BS5266-1

Daily Visually Check that all maintained lamps are operating and that all system healthy

Indicators on Central Power Supply Systems (sometimes called Central Battery Systems) are illuminated. Check that any recorded system fault Check that any recorded system fault

is given urgent attention and record all corrective actions in the logbook provided.

Monthly Check all luminaries and other emergency lighting equipment are in a

Good condition, all lamps and light controllers are clean, undamaged and not blackened.

Briefly test all emergency lighting equipment by simulating a failure of the normal lighting supply. The test should not exceed a quarter of the equipment rated duration. Check that all equipment functions correctly. Check that, upon restoring the mains supply, all supply healthy indicators are again illuminated.

Six Monthly Carry out the inspection and testing as described in the monthly test schedule, but conduct a test of the equipment for one third of its rated duration.

Annually A full system test should be conducted by a competent service engineer including a full rated duration test of the system.

Compliance of the installation and system with the requirements of BS 5266 should be considered and documented.

We offer a wide range of emergency lighting test and maintenance packages please call on 020 3633 3447 for detail or click below

FIRE EXTINGUISHER

On site Survey

Our fully trained technician will visit your building and survey your current fire extinguishers. They will advise on any alteration or additions required for you buildings fire extinguisher needs.

Service and Maintenance

Our qualified technician will attend site to carry out annual checks serving and overhall  on all your fire extinguishers in accordance with bs5306-6

Maintenance should be carried out by a competent person (usually a specialist contractor) 12 months after installation of a new extinguisher, and at 12 monthly intervals thereafter. 

We offer a comprehensive fire extinguisher service from site surveys to ensure you have the correct number and type in the correct locations in your building. We offer a great value supply only or supply and fit service. On top of this we offer a complete maintenance, service and training to ensure that all your extinguisher are working correctly.

Sales

We offer a full range of fire extinguishers. We can supply and commission all extinguishers on site to comply with BS5306-6. All our extinguishers come complete with service and maintenance options.

We offer a wide range of Fire Extinguisher and maintenance packages please call on 020 3633 3447 for detail or click below

FIRESAFETY TRAINING

For a business to be compliant with The Regulatory Reform (Fire Safety) Order 2005, training your staff is a very important. We offer training both on site and online in large number of subjects. Including ;-

•             Fire Marshall Training

•             Fire Extinguisher Training

•             Lifting and handling

•             Asbestos Awareness

•             Emergency Lighting Testing

•             And Many More

Please contact us to discuss your training needs

95cf6c_b23b2716f5024417ac5dea0a57eb1837-mv2

Fire Alarm Service AND Maintenance

Your fire alarm has been installed to protect the building and the lives of the people who use the building. It is of great importance that the fire alarm is functioning correctly at all times. This is achieved by regular testing servicing and maintenance. You have a legal obligation to ensure that the fire alarm system is in good working order and complies to current regulations and standards.

To comply with The Regulatory Reform (Fire Safety) Order 2005, your fire alarm should be tested once a week to ensure the system is operating. This is usually carried out by the premises manager and the recorded in the fire alarm log book. It is a legal requirement for the fire alarm system to be serviced at intervals of no more than 6months. One of qualified fire alarm engineers will attend site to carry out all the necessary tests and checks to ensure that your fire alarm is in good working order.

We offer an emergency call out service to give you the peace of mind, that if you have a problem with you fire alarm we will send out on of our fully qualified FIA trained fire alarm engineers to repair the fault and ensure that your fire alarm system is fully operational.

We offer a large number of packages to suit your business.

Bronze Package from £195 plus VAT

Carry out annual testing and maintenance of the fire alarm (2 visits)

Silver Package from £295 plus VAT

Carry out annual testing and maintenance of the fire alarm (2 visits)

Carry out an 1Hour and 3Hour Emergency lighting test.

Gold Package from £355 plus VAT

Carry out annual testing and maintenance of the fire alarm (2 visits)

Carry out an 1Hour and 3Hour Emergency lighting test.

Annual Fire Extinguisher Service.

Platinum Package from £595 plus VAT

Carry out annual testing and maintenance of the fire alarm (2 visits)

Carry out an 1Hour and 3Hour Emergency lighting test.

Annual Fire Extinguisher Service.

Annual Electrical Maintenance

Diamond Package from £2000 plus VAT

Weekly service visits to carry out Fire Alarm and Emergency lighting tests.

Carry out annual testing and maintenance of the fire alarm (2 visits).

Carry out an 1Hour and 3Hour Emergency lighting test.

Annual Fire Extinguisher Service.

Annual Electrical Maintenance.

We can also design a package to suit your needs

Please call us 0203633 3447 or fill in contact form below







Contact

Maple House

Maple Road

Surbiton

Surrey

KT6 4BA

T: 020 3633 3447


F: 020 3633 3447

info@kingstonfireandelectrical.co.uk

kingstonfireandelectrical.co.uk